What are the uses of copper flexible connectors
Views:  Addtime:2020-07-16
1. Copper foil flexible connection: also known as copper strip soft connection, copper sheet soft connection, made of high-quality 0.05 ~ 0.3mm thick copper foil as raw material. The laminated copper foil parts are pressed together, and the high current high temperature addition is carried out by the polymer diffusion welding machine, and the heat makes it split, melt and decompress.

2. Copper bus flexible connection: also known as copper bar flexible connection.

3. Flexible connection of copper stranded wire: stranded wire is used for the conductor, copper tube is selected at both ends, and the surface of copper tube is tinned. The standard of the connector is made according to the needs of customers, and then they are processed together for soft connection and soft grounding. The flexible connection guide rail of copper stranded wire has high electrification rate and strong anti fatigue ability. It is mainly used for soft connection of various high voltage electrical appliances, communication equipment, vacuum electrical appliances, mine explosion-proof switch and automobile and other related products. The quality risk brought by traditional cold binding process.

4. Soft connection of tinned copper strip: it is suitable for the soft connection of various high-voltage electrical appliances, vacuum electrical appliances, mine explosion-proof switches, automobiles, locomotives and other related products.

5.  Copper braided tape is used for transformer installation.
Application of copper soft connection: it can be used for transformer installation, high-voltage and low-voltage switchgear, vacuum electrical appliances, closing main slot, generator and bus, rectifier equipment, rectifier cabinet and disconnector connection and bus connection. It can improve the conductivity, adjust the installation error of the equipment, play the function of shock absorption compensation, and is convenient for detection and equipment overhaul.

What is the method of copper soft connection? In several cases, copper flexible connections are used:

1. Due to excessive short circuit current, many hard buses can not meet the requirements of dynamic stability, especially at the generator outlet.

2. The load current is relatively large, and the hard bus needs to be connected in parallel with multiple layers, so it is easy to install.

3. The phenomena of thermal expansion and cold contraction are considered.